Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 35

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

Model: MR-J4-_(-RJ)
Operation 0  to 55  (non-freezing)
Environment
Ambient
temperature
Storage
Ambient
Operation 5 %RH to 90 %RH (non-condensing)
humidity
Storage
Ambience
Altitude
Vibration resistance
Mass [kg]
*1 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points.
*2 Test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuit to self-
diagnose.
*3 Except for the terminal block.
*4 Follow the restrictions below when using the servo amplifiers at altitude exceeding 1000 m and up to 2000 m above sea level.
Page 81 Restrictions when using the servo amplifiers at altitude exceeding 1000 m and up to 2000 m above sea level
*5 The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input diagnosis by
TOFB output is performed or not. For details, refer to the Function column of [Pr. PF18] below.
Page 215 Extension setting 3 parameters ([Pr. PF_ _ ])
*6 The MR-J4-_GF servo amplifier is compatible only with the two-wire type. The MR-J4-_GF-RJ servo amplifier is compatible with the two-
wire type, four-wire type, and A/B/Z-phase differential output method.
Page 18 Summary
*7 The communication cycle depends on the controller specifications and the number of axes connected.
*8 Use an external dynamic brake for this servo amplifier. Failure to do so will cause an accident because the servo motor does not stop
immediately but coasts at emergency stop. Ensure the safety in the entire equipment.
*9 The external dynamic brake cannot be used for compliance with SEMI-F47 standard. Do not assign DB (Dynamic brake interlock) in [Pr.
PD07] to [Pr. PD09]. Doing so will cause the servo amplifier to become servo-off when an instantaneous power failure occurs.
*10 This is used with servo amplifiers with software version A1 or later.
60GF4
100GF4
200GF4
-20  to 65  (non-freezing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
*4
2000 m or less above sea level
5.9 m/, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
1.7
2.1
350GF4
500GF4
700GF4
3.6
4.3
6.5
1 FUNCTIONS AND CONFIGURATION
1.3 Servo amplifier standard specifications
11KGF4
15KGF4
22KGF4
13.4
13.4
18.2
1
33