Combination with MT-BR5-(H) resistor unit
■200 V class
MCCB
Power
supply
*1
Main circuit
*10
power supply
*12
24 V DC
*1 For the power supply specifications, refer to the following.
Page 30 Servo amplifier standard specifications
*2 Do not connect a supplied regenerative resistor to the P+ and C terminals.
*3 Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar between P3 and
P4. Additionally, a power factor improving DC reactor and power factor improving AC reactor cannot be used simultaneously.
Page 407 Power factor improving DC reactors
*4 Connect P/+ and N/- terminals of the brake unit to a correct destination. Incorrect connection destination results in servo amplifier and
brake unit malfunction.
*5 Contact rating: 1a contact, 110 V AC, 5 A/220 V AC, 3 A
Normal condition: TH1-TH2 is not conducting. Abnormal condition: TH1-TH2 is conducting.
*6 Contact rating: 230 V AC, 0.3 A/30 V DC, 0.3 A
Normal condition: B-C is conducting./A-C is not conducting. Abnormal condition: B-C is not conducting./A-C is conducting.
*7 Do not connect more than one cable to each P+ and N- terminals of the servo amplifier.
*8 Always connect BUE and SD terminals. (factory-wired)
*9 Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop deceleration to
shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn off the magnetic
contactor.
*10 Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo amplifier.
*11 When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
*12 The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be
configured by one.
ALM
OFF
RA1
Emergency stop switch
Servo amplifier
MC
*9
L1
CN3
L2
3
L3
L11
15
L21
*11
CN3
P3
EM2
20
P4
5
DICOM
P+
10
DICOM
*7
N-
C
ON
MC
MC
SK
24 V DC
*12
DOCOM
ALM
RA1
*3
*2
11 OPTIONS AND PERIPHERAL EQUIPMENT
RA2
MT-BR5
SK
TH1
*5
P
RA2
TH2
PR
FR-BU2
PR
MSG
P/+
SD
*4
A
N/-
B
C
BUE
*6
*8
SD
11.3 FR-BU2-(H) brake unit
11
359