11.4

FR-RC-(H) power regeneration converter

• When using the FR-RC-(H) power regeneration converter, set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced
stop 1).
• When using the FR-RC-(H) power regeneration converter, refer to "Power Regeneration Converter FR-RC
Instruction Manual (IB(NA)66330)".
When using the FR-RC-(H) power regeneration converter, set [Pr. PA02] to "_ _ 0 1" and set [Pr. PC20] to "_ _ _ 1".
Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to the servo amplifiers of
the 5 kW to 22 kW.
Power regeneration converter
FR-RC-15K
FR-RC-30K
FR-RC-55K
FR-RC-H15K
FR-RC-H30K
FR-RC-H55K
500
300
200
100
50
30
20
0
50
Nominal regenerative power [%]
Connection example
In this configuration, only the STO function is supported. The forced stop deceleration function is not
available.
11 OPTIONS AND PERIPHERAL EQUIPMENT
366
11.4 FR-RC-(H) power regeneration converter
Nominal regenerative power [kW]
15
30
55
15
30
55
75
100
150
Applicable servo amplifier
MR-J4-500GF(-RJ)
MR-J4-700GF(-RJ)
MR-J4-11KGF(-RJ)
MR-J4-15KGF(-RJ)
MR-J4-22KGF(-RJ)
MR-J4-500GF4(-RJ)
MR-J4-700GF4(-RJ)
MR-J4-11KGF4(-RJ)
MR-J4-15KGF4(-RJ)
MR-J4-22KGF4(-RJ)