No./symbol/
Setting
Function
name
digit
PL02
Set a linear encoder resolution with the settings of [Pr. PL02] and [Pr. PL03].
**LIM
Set a numerator to [Pr. PL02].
Linear encoder
This is enabled only for linear servo motors.
resolution -
Setting range: 1 to 65535
Numerator
PL03
Set a linear encoder resolution with the settings of [Pr. PL02] and [Pr. PL03].
**LID
Set a denominator to [Pr. PL03].
Linear encoder
This is enabled only for linear servo motors.
resolution -
Setting range: 1 to 65535
Denominator
PL04
_ _ _ x
[AL. 42 Servo control error] detection function selection
*LIT2
Refer to the following table.
Linear servo motor/
Setting
DD motor function
value
selection 2
0
1
2
3
4
5
6
7
*1 Refer to chapter 15 and 16 for details of each deviation error.
Page 486 Linear servo control error detection function
Page 506 Servo control error detection function
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
[AL. 42 Servo control error] detection function controller reset condition selection
0: Reset disabled (reset by powering off/on enabled)
1: Reset enabled
PL05
Set a position deviation error detection level of the servo control error detection.
LB1
When the deviation between a model feedback position and actual feedback position is larger than the
Position deviation
setting value, [AL. 42 Servo control error] will occur.
error detection level
However, when "0" is set, the level varies depending on the operation mode in [Pr. PA01].
Linear servo motor: 50 mm
Direct drive motor: 0.09 rev
Setting range: 0 to 1000
PL06
Set a speed deviation error detection level of the servo control error detection.
LB2
When the deviation between a model feedback speed and actual feedback speed is larger than the setting
Speed deviation
value, [AL. 42 Servo control error] will occur.
error detection level
However, when "0" is set, the level varies depending on the operation mode in [Pr. PA01].
Linear servo motor: 1000 mm/s
Direct drive motor: 100 r/min
Setting range: 0 to 5000
PL07
Set a torque/thrust deviation error detection level of the servo control error detection.
LB3
When the deviation between a current command and current feedback is larger than the setting value, [AL.
Torque/thrust
42.3 Servo control error by torque/thrust deviation] will occur.
deviation error
Setting range: 0 to 1000
detection level
PL08
_ _ _ x
Magnetic pole detection method selection
*LIT3
0: Position detection method
Linear servo motor/
4: Minute position detection method
DD motor function
_ _ x _
For manufacturer setting
selection 3
_ x _ _
Magnetic pole detection - Stroke limit enabled/disabled selection
0: Enabled
1: Disabled
x _ _ _
For manufacturer setting
Thrust/torque deviation
Speed deviation error
error
*1
Disabled
Disabled
Enabled
Enabled
Disabled
Enabled
Initial
value
[unit]
1000 [m]
1000 [m]
3h
Position deviation
*1
error
*1
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
0h
0h
0h
0 [mm]/
[0.01 rev]
0 [mm/s]/
[r/min]
100 [%]
0h
1h
0h
0h
5 PARAMETERS
5.2 Detailed list of parameters
5
219