No./symbol/
Setting
name
digit
PT29
Set the DOG polarity.
*TOP3
_ _ _ x
Function selection
(HEX)
T-3
_ _ x _
_ x _ _
x _ _ _
Convert the setting value into hexadecimal as follows.
0
PT41
_ _ _ x
ORP
Home position
return inhibit
_ _ x _
function selection
_ x _ _
x _ _ _
5 PARAMETERS
222
5.2 Detailed list of parameters
Function
_ _ _ x (BIN): DOG (Proximity dog) polarity selection
0: Dog detection with off
1: Dog detection with on
This setting is applied to both the input by a servo amplifier and by a controller.
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
For manufacturer setting
0
0
DOG (Proximity dog) polarity selection
«
«
«
Home position return inhibit selection
0: Disabled (home position return allowed)
1: Enabled (home position return inhibited)
For manufacturer setting
Initial value
Setting
BIN HEX
0
0
0
0
Initial
value
[unit]
0h
0h
0h
0h
0
0h
0h
0h
0h