Junction Terminal Block Ps7Dw-20V14B-F (Recommended) - Mitsubishi Electric MR-J4-10B(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 sscnet /h interface mr-j4 series servo amplifier
Table of Contents

Advertisement

11. OPTIONS AND PERIPHERAL EQUIPMENT

11.6 Junction terminal block PS7DW-20V14B-F (recommended)

(1) Usage
Always use the junction terminal block (PS7W-20V14B-F (Toho Technology)) with the option cable (MR-
J2HBUS_M) as a set. A connection example is shown below.
Ground the junction terminal block cable on the junction terminal block side with the supplied cable
clamp fitting (AERSBAN-ESET). For the use of the cable clamp fitting, refer to section 11.14, (2) (c).
(2) Connection of MR-J2HBUS_M cable and junction terminal block
Servo amplifier
Cable clamp
(AERSBAN-ESET)
CN3
MR-J2HBUS_M
Servo amplifier
CN3
(Note) MR-J2HBUS_M
LG
1
1
DI1
2
2
DOCOM
3
3
MO1
4
4
DICOM
5
5
LA
6
6
LB
7
7
LZ
8
8
INP
9
9
DICOM
10
10
LG
11
11
DI2
12
12
MBR
13
13
MO2
14
14
ALM
15
15
LAR
16
16
LBR
17
17
LZR
18
18
DI3
19
19
EM2
20
20
SD
Shell
Shell
Connector: 52316-2019 (Molex)
Shell kit: 52370-2070 (Molex)
Note. Symbol indicating cable length is put in _.
05: 0.5 m
1: 1 m
5: 5 m
11 - 50
Junction terminal block
PS7DW-20V14B-F
Junction terminal block
PS7DW-20V14B-F
CN
Terminal block
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
Shell Shell
1
LG
2
DI1
3
DOCOM
4
MO1
5
DICOM
6
LA
7
LB
8
LZ
9
INP
10
DICOM
11
LG
12
DI2
13
MBR
14
MO2
15
ALM
16
LAR
17
LBR
18
LZR
19
DI3
20
EM2
E
SD

Hide quick links:

Advertisement

Table of Contents
loading