[Blade damage prevention mode]
Adjusts the threshold temperature for preventing the cleaning blade in the transfer belt
3517
cleaning unit from being damaged. If the temperature is above this value, toner is applied
to the transfer belt at set intervals during the job to prevent the blade from flipping over.
001 Execution Temp. Threshold
[Toner End Prohibition Setting]
3519
Enables or disables each adjustment at toner near end.
001 Process Control
002 MUSIC
003 TC Adj.
[ITB Idling Number]
3520
Specifies the number of the ITB idling rotation for each condition.
001 Temperature: H
002 Temperature: M
003 Temperature: L
004 Temperature: L: Power ON
[Temperature Threshold]
Specifies the threshold temperature for each condition. These settings affect the conditions
3521
of SP3-520.
t1: Threshold between L (low temp.) and M (medium temp.)
t2: Threshold between M (medium temp.) and H (high temps)
001 Threshold: t2
002 Threshold: t1
*ENG
[0 to 50 / 40 / 1°C/step]
*ENG
[0 or 1 / 1 / 1/step]
0: Permit (adjustment is done even toner near
*ENG
end condition)
1: Forbid (adjustment is not done at toner near
*ENG
end condition)
*ENG
*ENG
[0 or 3 / 0 / 1 revolution/step]
*ENG
*ENG
*ENG
[20 or 30 / 25 / 1 deg/step]
*ENG
[0 or 15 / 15 / 1 deg/step]
Main SP Tables-3