CPM:M-humid
008
Specifies the CPM ratio of the decurl control against to the normal operation in middle
humidity.
CPM:H-humid
009
Specifies the CPM ratio of the decurl control against to the normal operation in high
humidity.
CPM:M-humid:No Decurl
010
Specifies the CPM ratio against of the no decurl control to the normal operation in middle
humidity.
CPM:H-humid:No Decurl
011
Specifies the CPM ratio against of the no decurl control to the normal operation in high
humidity.
1115
[Target Temp. Correction]
Temp.:Delta:End
001
Specifies the different temperature between end and center of the heating roller.
[CPM Down Setting]
1124
Specifies the settings for the CPM down mode.
001 Low:Down Temp.
Specifies the CPM down threshold temperature for the low temperature condition. If the
fusing temperature decreases -20°C (adjustable) below the target temperature, the
machine enters the CPM down mode.
002 Low:Up Temp.
Specifies the CPM up threshold temperature for the low temperature condition. If the fusing
temperature increases -15°C (adjustable) below the target temperature, the machine
enters the CPM up mode.
003 Low :1st CPM
Specifies the 1st CPM down ration against the normal CPM in the low temperature
condition.
*ENG
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 100 / 65 / 1 %/step]
*ENG
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 100 / 65 / 1 %/step]
*ENG
[-100 to 100 / 0 / 1 deg/step]
*ENG
[-50 to 0 / -20 / 1 deg/step]
*ENG
[-50 to 0 / -15 / 1 deg/step]
*ENG
[10 to 100 / 80 / 1 %/step]
Main SP Tables-1