3. SP Mode Tables
Preheat2:Center
003
Specifies the temperature of the pressure roller for the energy save 2 mode.
Preheat2:Press
004
Specifies the temperature of the pressure roller for the energy save 2 mode.
Low Power :Center
005
Specifies the temperature of the pressure roller for the low power mode.
Low Power:Press
006
Specifies the temperature of the pressure roller for the low power mode.
Print Ready:Center
007
Specifies the temperature of the heating roller for the print ready condition.
Print Ready:Press
008
Specifies the temperature of the pressure roller for the print ready condition.
Standby Heater Off Time
011
Specifies the time that the fusing heater turns off after the fusing unit temperature has
reached its target temperature.
1108
[After Reload/Job Target Temp.]
Center
001
Specifies the temperature of the heating roller after re-load or job.
Press
002
Specifies the temperature of the pressure roller after re-load or job.
Center:BW2
011
Specifies the temperature of the pressure roller after re-load or job in BW mode 2.
Press:BW2
012
Specifies the temperature of the pressure roller after re-load or job in BW mode 2.
58
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 60 / 1 deg/step]
[0 to 180 / C3c: 158, C3d: 161 / 1 deg/
*ENG
step]
*ENG
[0 to 200 / 120 / 1 deg/step]
*ENG
[0 to 100 / 15 / 1 sec/step]
[0 to 180 / C3c: 158, C3d: 161 / 1 deg/
*ENG
step]
*ENG
[0 to 200 / 120 / 1 deg/step]
[0 to 180 / C3c: 135(NA), 130(Other), C3d:
*ENG
140(NA), 135(Other) / 1 deg/step]
*ENG
[0 to 200 / 120 / 1 deg/step]