Extra Fan Cooling State
001
Displays the extra fan cooling is On or Off.
Extra Fan Cooling: Time:
002
Threshold
Extra Fan Cooling: Rotat:
003
Threshold
004 Extra Fan Cooling: Start Date
Extra Fan Cooling Time
005
Specifies the execution time for the extra fan cooling.
Execution Temp. Threshold
006
Specifies the judgment temperature for the starting of extra fan execution.
Cancellation Temp.
Threshold
007
Specifies the threshold temperature (the difference in value with the starting of extra fan
execution) for the cancellation of extra fan execution.
ON/OFF Setting
Enables or disenables the control of extra fan execution control.
008
0: Disenable
1: Enable
[Fan Control]
1955
Configures the settings of fan execution switching.
001 Execution Temp. Threshold
Cancellation Temp.
002
Threshold
[Extra Fan Control]
1954
Configures the settings of extra fan control.
[0 or 1 / - / 1 /step]
*ENG
0: Off, 1: On
*ENG
[0 to 180 / C3c: 80, C3d: 65 / 1 min./step]
*ENG
[0 to 999999999 / 0 / 1 min./step]
Displays the execution time and date of the
*ENG
extra fan cooling.
*ENG
[0 to 120 / 30 / 0.1 min./step:
*ENG
[20 to 70 / 37.3 / 0.1 deg/step]
*ENG
[0.1 to 20 / 4.5 / 0.1 deg/step]
*ENG
[0 to 1 / 1 / 1 /step]
*ENG
[20 to 70 / 34.6 / 0.1 /step]
*ENG
[0.1 to 20 / 1.8 / 0.1 /step]
Main SP Tables-1