5. System Maintenance
004 Low :2nd CPM
Specifies the 2nd CPM down ration against the normal CPM in the low temperature
condition.
005 Low :3rd CPM
Specifies the 3rd CPM down ration against the normal CPM in the low temperature
condition.
006 High :1st CPM
Specifies the 1st CPM down ration against the normal CPM in the high temperature
condition.
007 High:2nd CPM
Specifies the 3rd CPM down ration against the normal CPM in the high temperature
condition.
008 High:3rd CPM
Specifies the 1st CPM down ration against the normal CPM in the high temperature
condition.
High:1st CPM Down
009
Temp.:A3:Press End
Specifies the heating roller temperature for 1st CPM down of A3 paper size.
High:2nd CPM Down
010
Temp.:A3:Press End
Specifies the heating roller temperature for 2nd CPM down of A3 paper size.
High:3rd CPM Down
011
Temp.:A3:Press End
Specifies the heating roller temperature for 3rd CPM down of A3 paper size.
High:1st CPM Down
012
Temp.:DLT:Press End
Specifies the heating roller temperature for 1st CPM down of DLT paper size.
High:2nd CPM Down
013
Temp.:DLT:Press End
Specifies the heating roller temperature for 2nd CPM down of DLT paper size.
398
*ENG
[10 to 100 / 65 / 1 %/step]
*ENG
[10 to 100 / 50 / 1 %/step]
*ENG
[10 to 100 / 80 / 1 %/step]
*ENG
[10 to 100 / 50 / 1 %/step]
*ENG
[10 to 100 / 30 / 1 %/step]
*ENG
[100 to 250 / 180 / 1 deg/step]
*ENG
[100 to 250 / 185 / 1 deg/step]
*ENG
[100 to 250 / 190 / 1 deg/step]
*ENG
[100 to 250 / 180 / 1 deg/step]
*ENG
[100 to 250 / 185 / 1 deg/step]