Ricoh D143 Field Service Manual page 455

Table of Contents

Advertisement

004 Log Clear
[Environmental Correction: Transfer]
2302
Environmental Correction: Image Transfer Belt Unit
Current Environmental
001
Display
002 Forced Setting
Absolute Humidity:
003
Threshold 1
Absolute Humidity:
004
Threshold 2
Absolute Humidity:
005
Threshold 3
Absolute Humidity:
006
Threshold 4
007 Temp Threshold
[Paper Size Correction]
2308
Adjusts the threshold value for the paper size correction.
001 Threshold 1
[0 to 1 / 0 / 1/step]
-
1: Clear
-
Displays the current environment condition.
Sets the environment condition manually.
[0 to 6 / 0 / 1 /step]
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
*ENG
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
Adjusts the threshold value between LL and ML.
*ENG
[0 to 100 / 4 / 0.01 g/m
Adjusts the threshold value between ML and MM.
*ENG
[0 to 100 / 8 / 0.01 g/m
Adjusts the threshold value between MM and
MH.
*ENG
[0 to 100 / 16 / 0.01 g/m
Adjusts the threshold value between MH and HH.
*ENG
[0 to 100 / 24 / 0.01 g/m
*ENG
[–5 to 30 / 5 / 1 deg/step]
[0 to 350 / 297 / 1 mm/step]
*ENG
Threshold 1 ≤ paper:
Paper is detected as "S1" size.
Main SP Tables-2
3
/step]
3
/step]
3
/step]
3
/step]