Pressure roller overheat: End (hardware error)
The thermistor detects 220°C or more.
• Defective AC control board
• Defective IOB
• Defective IPU
• Defective fusing control system
1. Replace the AC control board.
564
A
2. Replace the IOB.
3. Replace the IPU.
4. Replace the fusing unit and reset the counter of the fusing unit using
SP3-902-014.
Important: The fusing unit cannot be used because an abnormal high temperature
was detected.
After this SC occurs, the counter reset of the fusing unit should be done manually
using SP3-902-014 because the counter reset is not done automatically.