No.
Type
Incorrect modem setting
Dial up fails due to the incorrect modem setting.
-04
-
Same as -01
1. Check and set the correct AT command (SP5-816-160).
Communication line error
The supplied voltage is not sufficient due to the defective communication line or
defective connection.
-05
-
Same as -01
1. Consult with the user's local telephone company.
No modem board
Modem board is not installed even though the setting at Cumin-M (During the
operation)
Same as -01
-13
-
1. Install the modem board if it is not installed.
2. Check correct setting value for modem driver (SP5-816-160, SP5-816-165
to 171, SP5-816-188 and 189).
3. Replace the modem board.
The modem board is installed
The modem board is installed even though the setting at Cumin-N. Or wired/
wireless LAN is not working normally.
-14
-
Same as -01
1. Uninstall the modem board if it is installed.
2. Check that the wired/wireless LAN is working properly.
No.
Type
651
C
Incorrect dial up connection
-01
-
Chat program parameter error
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)