Ricoh D143 Field Service Manual page 396

Table of Contents

Advertisement

5. System Maintenance
144 Postcard:Press
1106
[Fusing Temp. Display]
001 Heat: Center
002 Heat: End
003 Press: Center
004 Press: End
1107
[Standby Target Temp. Setting]
Standby/Preheat1:Center
001
Specifies the temperature of the pressure roller for the ready or energy save 1 mode.
Stanby/Preheat1: Press
002
Specifies the temperature of the pressure roller for the ready or energy save 1 mode.
Preheat2:Center
003
Specifies the temperature of the pressure roller for the energy save 2 mode.
Preheat2:Press
004
Specifies the temperature of the pressure roller for the energy save 2 mode.
Low Power :Center
005
Specifies the temperature of the pressure roller for the low power mode.
Low Power:Press
006
Specifies the temperature of the pressure roller for the low power mode.
Print Ready:Center
007
Specifies the temperature of the heating roller for the print ready condition.
Print Ready:Press
008
Specifies the temperature of the pressure roller for the print ready condition.
394
*ENG
[0 to 200 / 120 / 1 deg/step]
-
[-10 to 250 / - / 1 deg/step]
Displays the temperature of the heating roller.
-
-
[-10 to 250 / - / 1 deg/step]
Displays the temperature of the pressure roller.
-
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 90 / 1 deg/step]
*ENG
[0 to 125 / 60 / 1 deg/step]
[0 to 180 / C3c: 158, C3d: 161 / 1 deg/
*ENG
step]
*ENG
[0 to 200 / 120 / 1 deg/step]