Standby Heater Off Time
011
Specifies the time that the fusing heater turns off after the fusing unit temperature has
reached its target temperature.
1108
[After Reload/Job Target Temp.]
Center
001
Specifies the temperature of the heating roller after re-load or job.
Press
002
Specifies the temperature of the pressure roller after re-load or job.
Center:BW2
011
Specifies the temperature of the pressure roller after re-load or job in BW mode 2.
Press:BW2
012
Specifies the temperature of the pressure roller after re-load or job in BW mode 2.
1111
[Environment Correction:Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature. If the fusing temperature is 17°C
or less, the machine executes the fusing mode for low temperature.
Temp.: Threshold: High
002
Sepcifies the threshold temperature for high temperature. If the fusing temperature is 30°C
or more, the machine executes the fusing mode for high temperature.
Low Temp. Correction
003
Specifies the additional temperature for the target temperature. If the fusing temperature is
in low temperature condition, this temperature is added to the target temperature.
High Temp. Correction
004
Specifies the additional temperature for the target temperature. If the fusing temperature is
in high temperature condition, this temperature is added to the target temperature.
*ENG
[0 to 100 / 15 / 1 sec/step]
[0 to 180 / C3c: 158, C3d: 161 / 1 deg/
*ENG
step]
*ENG
[0 to 200 / 120 / 1 deg/step]
[0 to 180 / C3c: 135(NA), 130(Other), C3d:
*ENG
140(NA), 135(Other) / 1 deg/step]
*ENG
[0 to 200 / 120 / 1 deg/step]
*ENG
[0 to 100 / 17 / 1 deg/step]
*ENG
[0 to 100 / 30 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
Main SP Tables-1