Ricoh D143 Field Service Manual page 398

Table of Contents

Advertisement

5. System Maintenance
005 Job Low Temp. Correction
006 Job High Temp. Correction
Job Low Temp.
007
Correction:Sp.
Job High Temp.
008
Correction:Sp.
011 Standard Environment Temp.
1113
[Curl Correction]
Execute Pattern
001
Selects the curl correction type.
Humidity:Threshold:M-humid
002
Specifies the threshold between low and middle humidity.
Humidity:Threshold:H-humid
003
Specifies the threshold between middle and high humidity.
Permit Temp.:Delta:Press:M-
humid
004
Specifies the threshold temperature for the curl control in middle humidity.
Permit
humid
005
Specifies the threshold temperature for the curl control in high humidity.
Permit Temp.:Delta:Press:M-
006
humid:No Decurl
Specifies the threshold temperature for the no curl control in middle humidity.
Permit
007
humid:No Decurl
Specifies the threshold temperature for the no curl control in high humidity.
396
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
Temp.:Delta:Press:H-
*ENG
*ENG
Temp.:Delta:Press:H-
*ENG
[0 to 100 / 5 / 0.1 deg/step]
[0 to 100 / 0 / 0.1 deg/step]
[0 to 100 /10 / 0.1 deg/step]
[0 to 100 / 0 / 0.1 deg/step]
[10 to 30 / 23 / 1 deg/step]
[0 to 2 / 0 / 1 /step]
0: Off, 1: On (No Decurl), 2: On
[0 to 100 / 1 / 1 %/step]
[0 to 100 / 65 / 1 %/step]
[0 to 200 / 40 / 1 deg/step]
[0 to 200 / 30 / 1 deg/step]
[0 to 200 / 30 / 1 deg/step]
[0 to 200 / 20 / 1 deg/step]