Service Call Tables – 5 - Ricoh D143 Field Service Manual

Table of Contents

Advertisement

No.
Type
Temperature and humidity sensor error 2
• The thermistor output of the temperature sensor was not within the prescribed
• The thermistor output of the humidity sensor was not within the prescribed
498
C
• Temperature and humidity sensor harness disconnected, loose, defective
• Temperature and humidity sensor defective
1. Check the connector and harness.
2. Replace the temperature/humidity sensor.
Service Call Tables – 5
SC5xx: Paper Feed and Fusing
No.
Type
501
B
Paper Tray 1 error
502
B
Paper Tray 2 error
Details (Symptom, Possible Cause, Troubleshooting Procedures)
range (more than 0.5 V to less than 3.0 V).
range (less than 2.4 V).
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Service Call
803