Handytool Enumerations - Siemens Desigo RXB Technical Manual

Technical manual
Table of Contents

Advertisement

No.
1 - 3
5
6
8 - 10 Geographical zone
11 -13 Time switch zone
14
15
16
17
18
21
22 - 24 Master/slave zone
30 - 37 Setpoints
38
39
40
50
51
52
54
56
57
60
61
62
63
64
66
70
71
72
73
74
75
78
79
80
85
86
87
88
89
92
93
94
95
96
97
98
101
103
105
108
109
110
113
114
117
119
120
127
128
131
132
134
135
136
137
138
236
237
238
239
240
126/140
Siemens
Building Technologies
12.9

HandyTool enumerations

Parameter
Physical address
Plant type
Communications mode.
Heat distribution zone air heater.
Refrig distribution zone air cooler.
Heat distr zone heating surface
Refrig distr zone cooling surface
Outside temperature zone
Master/slave.
Minimum supply air temperature
Maximum supply air temperature
Risk of frost limit
Control sequence
Actuator type cool surf valve
Running time cool surface valve
Offset cooling surface valve
Electric heater
Power consumption el heater
Actuator type H/C coil valve
Running time damper heating
Running time damper cooling
Actuator type heat surf valve
Running time heat surface valve
Offset heating surface valve
Changeover time damper
Offset heating valve
Offset cooling valve
Outside temp min damper pos
Running time outside air damper
Minimum damper position
Outside temp 0% valve pos
Outside temp max valve pos
Max valve position
Heating (coil) outp bus valve
Heating surface output bus valve actuator
Cooling (coil) outp bus valve
Cooling surface outp bus valve,
Heating outp bus el heating
Temperature sensor.
Fan control
Fan speeds
Minimum on time
Periodic fan kick Comfort
Periodic fan kick Eco
Fan overrun time
Measured value correction
Setpoint offset range
Local Comfort mode
Temperature unit
Standard display
Setpoint display
Digital input 1
Digital input 2
Temporary Comfort mode
On-delay occupancy detector
Off-delay occupancy detector
Send heartbeat
Receive timeout
Heat demand signal
Cooling demand signal
Boost heating
Preecooling / Free cooling
Rapid ventilation (earlier: air purge)
Reset setpoint offset
Night purge
Application set
Application version
Operating system version
KNX interface version
Device state
RXB (KNX) Applications library
KNX information
X
X
X
X
FC-10
X
X
0 = S-Mode
1 = FNC02
X
X
1 = S+LTE-M
2 = FNC04
X
X
3 = FNC08
X
4 = FNC20
X
X
X
X
X
X
X
X
0 = Slave
X
X
1 = Master
X
X
C: Prot / Eco / Pre-C / Comf
X
X
X
X
0 = c/o
/
1 = Cooling
X
VA
VA = Valve actuators:
X
X
1
= on/off
1 = STE71
X
254 = continuous
3 = STA71
X
4 = STP71
X
VA
5 = STA72E
X
6 = STP72E
X
X
X
VA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0 = OFF
X
1 = ON
X
X
X
X
0 = Ret. air
/
1 = Room
X
0 = manual
/
1 = automatic
X
0 = automatic / 1 = 1-stage / 2 = 2-stage / 3 = 3-stage
X
X
X
X
X
X
X
X
X
X
0 = disabled
/
1 = enabled
X
X
0 = °F
/
1 = °C
X
X
2 = Room temp.
/
48 = Setpoint
X
X
0 = relative
/
4 = absolute
X
X
0 = BUS 1 /
X
X
1 = BUS 1 /
X
X
2 = Occup /
X
X
3 = Occup /
X
X
4 = Wind. open / Contact open
X
X
5 = Wind. open / Contact closed
X
X
X
X
X
X
0 = OFF
X
X
1 = ON
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CLC and RAD description of functions for CC-02 CM110384en_03
FC-11
FC-12
1 = FNC10
1 = FNC03
2 = FNC12
2 = FNC05
3 = FNC18
H: Comf / Pre-C / Eco / Prot
/
2 = Heating
10 = SSA81
250 = Mot BUS
11 = SSB81
252 = El-mech 3rd
12 = SQS81
253 = Therm. 3rd
13 = SSC81
254 = Mot. 3rd
14 = SSP 81
/
3 = Meas. val. /
255 = No sensor
/
96 = No display
Contact closed
8 = Dewpt. /
Contact open
9 = Dewpt. /
Contact closed
16 = Overt. /
Contact open
17 = Overt. /
32 = Frost /
33 = Frost /
CC-02
1 = CLC01
2 = CLC02
3 = RAD01
.
.
.
.
.
Contact closed
Contact open
Contact open
Contact closed
Contact closed
Contact open
28 Feb 2009