S-Mode Communication Objects For Rad/Clc; 12.5.1 S-Mode Input Communication Objects - Siemens Desigo RXB Technical Manual

Technical manual
Table of Contents

Advertisement

Name
Application mode
Comfort cooling setpoint
Comfort heating setpoint
Cooling surface valve override 0 1 1 0 0 8.010
Economy cooling setpoint
Economy heating setpoint
Enable alarm info
Heating surface valve override 0 1 1 0 0 8.010
Master/slave HVAC controller
input
Master/slave room unit input
Outside temperature
Precomfort cooling setpoint
Precomfort heating setpoint
Presence detector input
Room dewpoint alarm input
Room temperature input
Setpoint ... (6 indiv. values)
Setpoint offset
Setpoints cooling
Setpoints heating
Setpoint shift cooling
Setpoint shift heating
Status request
Temporary Comfort mode
Triac Y1
Triac Y2
Triac Y3
Triac Y4
Schedule occupancy
Schedule room operating
mode
Schedule usage
Window switch input
Siemens
Building Technologies
12.5

S-mode communication objects for RAD/CLC

12.5.1 S-mode input communication objects

Flags:
R
Read
W Write
C
Communication
Flags:
Data point type (KONNEX)
R W C T U
0 1 1 0 0 20.105
0 1 1 1 0 9.001
0 1 1 1 0 9.001
0 1 1 1 0 9.001
0 1 1 1 0 9.001
0 1 1 0 0 1.003
0 1 1 0 0 C.S.
0 1 1 0 0 C.S.
0 1 1 1 1 9.001
0 1 1 1 0 9.001
0 1 1 1 0 9.001
0 1 1 0 0 1.018
0 1 1 1 1 1.005
0 1 1 1 1 9.001
0 1 1 0 0 9.001
0 1 1 0 0 9.002
0 1 1 0 0 222.100
0 1 1 0 0 222.100
0 1 1 0 0 222.101
0 1 1 0 0 222.101
0 1 1 0 0 C.S.
0 1 1 0 0 1.017
0 1 1 0 0 1.001
0 1 1 0 0 1.001
0 1 1 0 0 1.001
0 1 1 0 0 1.001
0 1 1 0 0 20.003
0 1 1 0 0 20.102
0 1 1 0 0 20.002
0 1 1 0 0 1.019
RXB (KNX) Applications library
KNX information
T
Transmit
U
Update
1)
C.S. = Company specific
For internal use only
DPT_HVACContrMode
DPT_Value_Temp
DPT_Value_Temp
DPT_Percent_V16
DPT_Value_Temp
DPT_Value_Temp
DPT_Enable
DPT_Percent_V16
1)
13 Byte
1)
4 Byte
DPT_Value_Temp
DPT_Value_Temp
DPT_Value_Temp
DPT_Occupancy
DPT_Alarm
DPT_Value_Temp
DPT_Value_Temp
DPT_Value_Tempd
DPT_TempRoomSetpSetF16[3]
DPT_TempRoomSetpSetF16[3]
DPT_TempRoomSetpSetShiftF16[3]
DPT_TempRoomSetpSetShiftF16[3]
1)
1 Byte
DPT_Trigger
DPT_Switch
DPT_Switch
DPT_Switch
DPT_Switch
DPT_OccMode
DPT_HVACMode
DPT_BuildingMode
DPT_Window_Door
CLC and RAD description of functions for CC-02 CM110384en_03
Receive
See
timeout
Page
Yes
105
No
70
No
70
No
90, 93,
103
No
70
No
70
Yes
109
No
93, 103
Yes
95
Yes
95
Yes
78
No
70
No
70
No
38
Yes
Yes
77
No
70
No
72
No
70
No
70
Yes
72
Yes
72
No
117
No
40
No
112
No
112
No
112
No
112
Yes
37
Yes
47
Yes
36
No
34
119/140
28 Feb 2009