LOCAL/REMOTE CONTROL APPLICATION
Table 16: Input signals, G2.2
Index
Parameter
Place A Reference
P2.2.17
scaling maximum
value
Place B Reference
P2.2.18
scaling minimum
value
Place B Reference
P2.2.19
scaling maximum
value
Free analogue
P2.2.20
input, signal
selection
Free analogue
P2.2.21
input, function
Motor potentiom-
P2.2.22
eter ramp time
Motor potentiom-
eter frequency
P2.2.23
reference mem-
ory reset
Start pulse mem-
P2.2.24
ory
** = Remember to place jumpers of block X2 accordingly. See the product's User Manual.
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM
Min
Max
Unit
0.00
0.00
320.00
Hz
0.00
320.00
Hz
0
2
0
4
0.1
2000.0
Hz/s
0
2
0
1
Default
Cust
ID
304
0.00
364
0.00
365
0
361
0
362
10.0
331
1
367
0
498
VACON · 53
Description
Selects the fre-
quency that corre-
sponds to the max.
reference signal 0.00
= No scaling >0 =
scaled max. value.
Selects the fre-
quency that corre-
sponds to the min.
reference signal.
Selects the fre-
quency that corre-
sponds to the max.
reference signal.
0.00 = No scaling
>0 = scaled max.
value
0 = Not used
1 = Analogue input 1
2= Analogue input 2
0 = No reset
1 = Reduces current
limit (P2.1.5)
2 = Reduces DC
braking current
3 = Reduces accel.
and decel. times
4 = Reduces torque
super vision limit
0 = No reset
1 = Reset if stopped
or powered down
2 = Reset if powered
down
0 = Run state not
copied
1 = Run state copied
3