VACON · 284
Table 143: Selections for parameter ID371
Selection
number
0
AI1 reference
1
AI2 reference
2
AI3 reference
3
AI4 reference
4
PID reference 1 from keypad
Reference from Fieldbus
5
(FBProcessDataIN3)
Motor potentiometer
6
7
PID reference 2 from keypad
372 SUPERVISED ANALOGUE INPUT 7 (2.3.2.13)
Table 144: Selections for parameter ID372
Selection
number
0
Analogue input 1 (AI1)
1
Analogue input 2 (AI2)
373 ANALOGUE INPUT LIMIT SUPERVISION 7 (2.3.2.14)
If the value of the selected analogue input goes under/over the set supervision value
(parameter ID374) this function generates a message through the digital output or the relay
outputs depending on to which output the analogue input supervision function (parameter
ID463) is connected.
Table 145: Selections for parameter ID373
Selection
number
0
No supervision
1
Low limit supervision
2
High limit supervision
8
Selection name
(terminals 2 and 3, e.g. potentiometer)
(terminals 5 and 6, e.g. transducer)
see Chapter 8.7 Fieldbus control parameters (IDs 850 to 859)
If value 6 is selected for this parameter, the functions Motor
potentiometer DOWN and Motor potentiometer UP must be
connected to digital inputs (parameters ID417 and ID418).
Selection name
Selection name
PARAMETER DESCRIPTIONS
Description
Description
Description