VACON · 250
300 START/STOP LOGIC SELECTION 2346 (2.2.1, 2.2.1.1)
Table 115: Selections for parameter ID300
Selection
closed contact = start forward
0
See Fig. 30.
closed contact = startopen
contact = stop
1
See Fig. 31.
closed contact = startopen
2
contact = stop
closed contact= start pulse
3 *
See Fig. 32.
Applications 2 and 4:
closed contact = start forward
4
(Rising edge required to start)
closed contact = start (Rising
5
edge required to start)
open contact = stop
closed contact = start (Rising
6
edge required to start)
open contact = stop
Applications 3 and 6:
closed contact = start forward
4
closed contact = start forward
5
(Rising edge required to start)
closed contact = start (Rising
6
edge required to start)
open contact = stop
8
DIN1
closed contact = start reverse
closed contact = reverseopen
contact = forward
closed contact = start enable-
dopen contact = start disabled
and drive stopped if running
open contact = stop pulse
closed contact = start reverse
(Rising edge required to start)
closed contact = reverse
open contact = forward
closed contact = start enabled
open contact = start disabled
and drive stopped if running
closed contact = reference
increases (motor potentiome-
ter reference; this parameter
is automatically set to 4 if
parameter ID117 is set to 4
[Application 4]).
closed contact = start reverse
(Rising edge required to start)
closed contact = reverse
open contact = forward
DIN2
can be programmed for reverse
command
can be programmed for reverse
command
can be programmed for reverse
command unless selected for
DIN2
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205