Vacon NX series Applications Manual page 171

All in one
Hide thumbs Also See for NX series:
Table of Contents

Advertisement

MULTI-PURPOSE CONTROL APPLICATION
Table 72: NXS drives: Closed Loop parameters (Control keypad: Menu M2 ->G2.6.23)
Index
Parameter
Magnetizing cur-
P2.6.17.1
rent
P2.6.17.2
Speed control P
Speed control I
P2.6.17.3
time
Acceleration
P2.6.17.5
compensation
P2.6.17.6
Slip adjust
Magnetizing cur-
P2.6.17.7
rent at start
Magnetizing time
P2.6.17.8
at start
0-speed time at
P2.6.17.9
start
0-speed time at
P2.6.17.10
stop
P2.6.17.11
Start-up torque
Start-up torque
P2.6.17.12
FWD
Start-up torque
P2.6.17.13
REV
Encoder filter
P2.6.17.15
time
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM
Min
Max
Unit
0.00
2 x I
A
H
1
1000
-3200.0
3200.0
ms
0.00
300.00
s
0
500
%
0.00
I
A
L
0
32000
ms
0
32000
ms
0
32000
ms
0
3
-300.0
300.0
s
-300.0
300.0
s
0.0
100.0
ms
Default
Cust
ID
0.00
612
30
613
100.0
614
0.00
626
75
619
0.00
627
0
628
100
615
100
616
0
621
0.0
633
0.0
634
0.0
618
VACON · 171
Description
If zero internally
calculated.
Negative value
uses 1 ms accu-
racy instead of 0.1
ms.
0 = Not used
1 = Torque mem-
ory
2 = Torque refer-
ence
3 = Start-up torque
fwd/rev
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxp seriesNxs series

Table of Contents