Vacon NX series Applications Manual page 48

All in one
Hide thumbs Also See for NX series:
Table of Contents

Advertisement

VACON · 48
Table 15: Basic parameters G2.1
Index
Parameter
P2.1.10 *
Motor cos phi
P2.1.11 *
I/O A reference
P2.1.12 *
I/O B reference
Keypad control
P2.1.13 *
reference
Fieldbus control
P2.1.14 *
reference
Jogging speed
P2.1.15 *
reference
* = Parameter value can only be changed after the AC drive has been stopped.
3
Min
Max
Unit
0.30
1.00
0
4
0
4
0
3
0
3
0.00
P2.1.2
Hz
LOCAL/REMOTE CONTROL APPLICATION
Default
Cust
ID
0.85
120
1
117
0
131
2
121
3
122
0.00
124
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205
Description
Find the value on
the rating plate of
the motor.
0 = AI1
1 = AI2
2 = Keypad
3 = Fieldbus
4 = Motor potenti-
ometer
0 = AI1
1 = AI2
2 = Keypad
3 = Fieldbus
4 = Motor potenti-
ometer
0 = AI1
1 = AI2
2 = Keypad
3 = Fieldbus
0 = AI1
1 = AI2
2 = Keypad
3 = Fieldbus

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxp seriesNxs series

Table of Contents