VACON · 50
Table 16: Input signals, G2.2
Index
Parameter
Place A Start/Stop
P2.2.1 ***
logic selection
P2.2.2
DIN3 function
P2.2.3
AI1 signal selec-
****
tion
P2.2.4
AI1 signal range
AI1 custom set-
P2.2.5
ting minimum
AI1 custom set-
P2.2.6
ting maximum
3
Min
Max
Unit
0
8
0
13
0.1
E.10
0
2
-160.00
160.00
%
-160.00
160.00
%
LOCAL/REMOTE CONTROL APPLICATION
Default
Cust
ID
0
300
1
301
A1
377
0
320
0.00
321
100.00
322
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205
Description
Logic = 8
Ctrl sgn 1 = Start
forward (edge)
Ctrl sgn 2 = Motor
potentiometer UP
0 = Not used
1 = Ext. fault, closing
cont.
2 = Ext. fault, open-
ing cont.
3 = Run enable
4 = Acc./Dec. time
select.
5 = Force cp. to IO
6 = Force cp. to key-
pad
7 = Force cp. to
fieldbus
8 = Reverse
9 = Jogging speed
10 = Fault reset
11 = Acc./Dec. oper-
ation prohibit
12 = DC Braking
command
13 = Motor potenti-
ometer DOWN
TTF programming
method used. See
Chapter 8.9 "Termi-
nal to function" (TTF)
programming princi-
ple.
0 = 0-10V (0-20
mA**)
1 = 2-10V (4-20
mA**)
2 = Custom setting
range**
Analogue input 1
scale minimum.
Analogue input 1
scale maximum.