VACON · 160
Table 65: Limit settings (Control keypad: Menu M2 -> G2.3.4)
Index
Parameter
Output frequency
P2.3.4.1
limit 1 supervision
Output frequency
P2.3.4.2
limit 1; Supervised
value
Output frequency
P2.3.4.3
limit 2 supervision
Output frequency
P2.3.4.4
limit 2; Supervised
value
Torque limit
P2.3.4.5
supervision
Torque limit
P2.3.4.6
supervision value
Reference limit
P2.3.4.7
supervision
Reference limit
P2.3.4.8
supervision value
6
Min
Max
Unit
0
3
0.00
320.00
Hz
0
4
0.00
320.00
Hz
0
3
-300.0
300.0
%
0
2
0.0
100.0
%
MULTI-PURPOSE CONTROL APPLICATION
Default
Cust
ID
0
315
0.00
316
0
346
0.00
347
0
348
100.0
349
0
350
0.0
351
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205
Description
0 = No supervision
1 = Low limit
supervision
2 = High limit
supervision
3 = Brake-on con-
trol
0 = No supervision
1 = Low limit
supervision
2 = High limit
supervision
3 = Brake-off con-
trol
4 = Brake on/off
control
0 = No supervision
1 = Low limit
supervision
2 = High limit
supervision
3 = Brake-off con-
trol
For brake control
absolute values
are used.
0 = No supervision
1 = Low limit
2 = High limit
0.0 = Min fre-
quency
100.0 = Max fre-
quency

Hide quick links: