Ca Type (Fr-A800-E) - Mitsubishi Electric FR-A820-00046 Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Installation and wiring
2.4.3

CA type (FR-A800-E)

Source logic
Main circuit terminal
Control circuit terminal
MCCB
Three-phase AC
power supply
Jumper
Control input signals
(No voltage input allowed)
Forward rotation start
Reverse rotation start
Start self-holding selection
High speed
Multi-speed
Multi-speed
Middle speed
selection
selection
Low speed
Jog operation
Second function selection
Output stop
Reset
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous power failure
Common for external power
supply transistor
Contact input common
24 V DC power supply
24 V external power supply input
Common terminal
Frequency setting signal (analog)
3
Frequency setting
2
potentiometer
Ω
1/2 W, 1 k
1
Auxiliary
(+)
input
(-)
Terminal 4 input
(+)
(Current input)
(-)
Connector for plug-in option connection
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
Fig. 2-19:
Terminal connection diagram of the inverter (CA type) (FR-A800-E)
FR-A800
DC reactor
(FR-HEL)
Jumper
Jumper
Earth
(Ground)
P1
P/+
PX
R
MC
Inrush
R/L1
current limit
S/L2
circuit
T/L3
ON
R1/L11
S1/L21
OFF
Main circuit
Earth
Control circuit
(Ground)
STF
STR
STP(STOP)
RH
RM
RL
JOG
RT
MRS
RES
AU
CS
SD
24V
PC
+24
Voltage/current
SD
input switch
10E(+10V)
ON
OFF
10(+5V)
2
4
Initial value
0–5 V DC
2
0–10 V DC
selectable
4–20 mA DC
5
(Analog common)
Initial
0–±10 V DC
value
1
0–±5 V DC
selectable
4–20 mA DC
Initial value
4
0 –5 V DC
selectable
0–10 V DC
Connector 1
Connector 2
Connector 3
24V
Shorting
wire
PC
S1
Output
S2
shutoff circuit
SIC
SD
Brake resistor
(FR-ABR)
Brake unit
(Option)
R
(Ground)
PR
N/-
U
V
W
EMC filter
ON/OFF
connector
C1
B1
Relay output 1
(Fault output)
A1
C2
B2
Relay output 2
A2
RUN
Running
SU
Up to frequency
IPF
Instantaneous power failure
OL
Overload
FU
Frequency detection
SE
Open collector output common
Sink/source common
PU
connector
F/C
USB A
(CA)
connector
USB
mini B
AM
connector
5
Ethernet
connector
SO
Safety monitor output
SOC
Safety monitor output common
Terminal connection diagrams
FR-A820-00770(15K) to 01250(22K),
FR-A840-00470(18.5K) to 01800(55K)
Brake resistor
DC reactor
(FR-HEL)
Brake unit
(Option)
R
Jumper
Earth
P1
P/+
P3
PR
N/-
Inrush
current limit
circuit
Motor
M
Earth (Ground)
Relay output
Open collector output
Analog current output
(0 to 20 mA DC)
Analog signal output
(0 to ±10 V DC)
I002356E_2_F
2 - 25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents