Installation and wiring
Switches of the FR-A8AP
● Encoder type selection switch (SW3)
Selects either the differential line driver or complementary setting.
It is initially set to the differential line driver. Switch its position according to the output circuit.
● Terminating resistor selection switch (SW1)
Selects ON/OFF of the internal terminating resistor.
Set the switch to ON (initial status) when an encoder output type is differential line driver, and set
to OFF when complementary.
ON: with internal terminating resistor (initial status)
OFF: without internal terminating resistor
Internal terminating
resistor-ON
(initial status)
Internal terminating
resistor-OFF
NOTES
Set all switches to the same setting (ON/OFF).
Set the switch "OFF" when sharing an encoder with another unit (NC (computerized numerical
controller), etc.) having a terminating resistor under the differential line driver setting.
FR-A800
Differential line
driver (initial status)
1
O
2
N
SW2
SW3
Complementary
1
O
2
N
SW2
Connection of motor with encoder (vector control)
Fig. 2-49:
Encoder specification selection switch
Fig. 2-50:
Terminating resistor selection switch
SW3
I002386E