15-** Drive Information - Danfoss VLT Midi Drive FC 280 Programming Manual

Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Parameter Lists
Parameter #
14-22
14-24
14-25
14-27
14-28
14-29
14-3* Current Limit Ctrl.
5
5
14-30
14-31
14-32
14-4* Energy Optimising
14-40
14-41
14-44
14-5* Environment
14-50
14-51
14-52
14-55
14-6* Auto Derate
14-61
14-63
14-64
14-65
14-8* Options
14-89
14-9* Fault Settings
14-90

5.2.15 15-** Drive Information

Parameter #
15-0* Operating Data
15-00
15-01
15-02
15-03
15-04
15-05
15-06
15-07
15-3* Alarm Log
15-30
15-31
116
Parameter description
Operation Mode
Trip Delay at Current Limit
Trip Delay at Torque Limit
Action At Inverter Fault
Production Settings
Service Code
Current Lim Ctrl, Proportional
Gain
Current Lim Ctrl, Integration Time
Current Lim Ctrl, Filter Time
VT Level
AEO Minimum Magnetisation
d-axis current optimization for
IPM
RFI Filter
DC-Link Voltage Compensation
Fan Control
Output Filter
Function at Inverter Overload
Min Switch Frequency
Dead Time Compensation Zero
Current Level
Speed Derate Dead Time
Compensation
Option Detection
Fault Level
Parameter description
Operating hours
Running Hours
kWh Counter
Power Up's
Over Temp's
Over Volt's
Reset kWh Counter
Reset Running Hours Counter
Alarm Log: Error Code
InternalFaultReason
Danfoss A/S © 07/2016 All rights reserved.
®
VLT
Midi Drive FC 280
Default value
4 set-up
[0] Normal
operation
1 set-up
60 s
All set-ups
60 s
All set-ups
[1] Warning
All set-ups
[0] No action
1 set-up
0 N/A
1 set-up
100 %
All set-ups
0.020 s
All set-ups
5 ms
All set-ups
66 %
All set-ups
66 %
All set-ups
100 %
All set-ups
[2] Grid Type
1 set-up
[1] On
All set-ups
[5] Constant-on
mode
1 set-up
[0] No Filter
1 set-up
[0] Trip
All set-ups
[2] 2.0 kHz
1 set-up
[0] Disabled
All set-ups
Size Related
All set-ups
[0] Protect Option
Config.
1 set-up
[3] Trip Lock
All set-ups
Default value
4 set-up
0 h
1 set-up
0 h
1 set-up
0 kWh
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[0] Do not reset
1 set-up
[0] Do not reset
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
Change during
Conversion
operation
index
TRUE
-
TRUE
0
TRUE
0
TRUE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
-3
TRUE
-4
FALSE
0
FALSE
0
TRUE
0
FALSE
-
FALSE
-
TRUE
-
FALSE
-
TRUE
-
FALSE
-
FALSE
-
FALSE
0
TRUE
-
TRUE
-
Change during
Conversion
operation
index
TRUE
74
TRUE
74
TRUE
75
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Type
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Uint8
Uint8
Uint8
Int16
MG07C302