30-** Special Features; 32-** Motion Control Basic Settings; 33-** Motion Control Adv. Settings; 34-** Motion Control Data Readouts - Danfoss VLT Midi Drive FC 280 Programming Manual

Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Parameter Lists

5.2.20 30-** Special Features

Parameter #
30-2* Adv. Start Adjust
30-20
30-21
30-22
30-23

5.2.21 32-** Motion Control Basic Settings

5
5
Parameter #
32-11
32-12
32-67
32-80
32-81

5.2.22 33-** Motion Control Adv. Settings

Parameter #
33-00
33-01
33-02
33-03
33-04
33-41
33-42
33-43
33-44
33-47

5.2.23 34-** Motion Control Data Readouts

Parameter #
34-0* PCD Write Par.
34-01
34-02
34-03
34-04
34-05
34-06
34-07
34-08
34-09
34-10
34-2* PCD Read Par.
34-21
120
Parameter description
High Starting Torque Time [s]
High Starting Torque Current [%]
Locked Rotor Detection
Locked Rotor Detection Time [s]
Parameter description
User Unit Denominator
User Unit Numerator
Max. Tolerated Position Error
Maximum Allowed Velocity
Motion Ctrl Quick Stop Ramp
Parameter description
Homing Mode
Home Offset
Home Ramp Time
Homing Velocity
Homing Behaviour
Negative Software Limit
Positive Software Limit
Negative Software Limit Active
Positive Software Limit Active
Target Position Window
Parameter description
PCD 1 Write For Application
PCD 2 Write For Application
PCD 3 Write For Application
PCD 4 Write For Application
PCD 5 Write For Application
PCD 6 Write For Application
PCD 7 Write For Application
PCD 8 Write For Application
PCD 9 Write For Application
PCD 10 Write For Application
PCD 1 Read For Application
Danfoss A/S © 07/2016 All rights reserved.
®
VLT
Midi Drive FC 280
Default value
4 set-up
Size Related
All set-ups
Size Related
All set-ups
[0] Off
All set-ups
0.10 s
All set-ups
Default value
4 set-up
1 N/A
1 set-up
1 N/A
1 set-up
2000000 N/A
1 set-up
1500 RPM
1 set-up
1000 ms
1 set-up
Default value
4 set-up
[0] Not forced
1 set-up
0 N/A
1 set-up
10 ms
1 set-up
100 RPM
1 set-up
[1] Reverse no
index
1 set-up
-500000 N/A
1 set-up
500000 N/A
1 set-up
[0] Inactive
1 set-up
[0] Inactive
1 set-up
0 N/A
1 set-up
Default value
4 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Change during
Conversion
operation
index
TRUE
-2
TRUE
-1
TRUE
-
TRUE
-2
Change during
Conversion
operation
index
FALSE
0
FALSE
0
TRUE
0
FALSE
67
TRUE
-3
Change during
Conversion
operation
index
TRUE
-
TRUE
0
TRUE
-3
TRUE
67
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
Change during
Conversion
operation
index
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
Type
Uint16
Uint32
Uint8
Uint8
Type
Uint32
Uint32
Uint32
Uint16
Uint32
Type
Uint8
Int32
Uint16
Int16
Uint8
Int32
Int32
Uint8
Uint8
Uint16
Type
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
MG07C302