Parameter Descriptions
0-24 Display Line 3 Large
Select a variable to show in line 3.
Option:
[2119]
Ext. 1 Output [%]
[3401]
PCD 1 Write For Application
[3402]
PCD 2 Write For Application
[3403]
PCD 3 Write For Application
[3404]
PCD 4 Write For Application
[3405]
PCD 5 Write For Application
[3406]
PCD 6 Write For Application
[3407]
PCD 7 Write For Application
[3408]
PCD 8 Write For Application
[3409]
PCD 9 Write For Application
[3410]
PCD 10 Write For Application
[3421]
PCD 1 Read For Application
[3422]
PCD 2 Read For Application
[3423]
PCD 3 Read For Application
[3424]
PCD 4 Read For Application
[3425]
PCD 5 Read For Application
[3426]
PCD 6 Read For Application
[3427]
PCD 7 Read For Application
[3428]
PCD 8 Read For Application
[3429]
PCD 9 Read For Application
[3430]
PCD 10 Read For Application
[3450]
Actual Position
[3456]
Track Error
0-30 Custom Readout Unit
Set a value to be shown in the LCP. The value has a linear,
squared, or cubed relation to speed. This relation depends on the
unit selected.
Option:
[0]
None
[1]
%
*
[5]
PPM
[10]
1/min
[11]
RPM
[12]
Pulse/s
[20]
l/s
[21]
l/min
[22]
l/h
[23]
m³/s
[24]
m³/min
[25]
m³/h
[30]
kg/s
[31]
kg/min
[32]
kg/h
[33]
t/min
[34]
t/h
[40]
m/s
[41]
m/min
[45]
m
[60]
°C
[70]
mbar
MG07C302
Programming Guide
0-30 Custom Readout Unit
Set a value to be shown in the LCP. The value has a linear,
squared, or cubed relation to speed. This relation depends on the
Function:
unit selected.
Option:
[71]
[72]
[73]
[74]
[80]
[120]
[121]
[122]
[123]
[124]
[127]
[140]
[141]
[160]
[170]
[171]
[172]
[173]
[180]
0-31 Custom Readout Min Value
Range:
0 CustomRea-
doutUnit
Function:
0-32 Custom Readout Max Value
Range:
100 Custom-
ReadoutUnit
0-37 Display Text 1
Range:
[0 - 0 ] Free text, for example used for the device tag of
Danfoss A/S © 07/2016 All rights reserved.
bar
Pa
kPa
m WG
kW
GPM
gal/s
gal/min
gal/h
CFM
ft³/h
ft/s
ft/min
°F
psi
lb/in2
in WG
ft WG
HP
Function:
[ 0 -
This parameter sets the
999999.99
minimum value of the custom
*
CustomRea-
readout (occurs at 0 speed). It is
doutUnit]
only possible to select a value
different from 0 when selecting a
linear unit in
parameter 0-30 Custom Readout
Unit. For quadratic and cubic
units, the minimum value is 0.
Function:
[ 0.0 -
This parameter sets the
999999.99
maximum value to be shown
*
CustomRea-
when the motor speed has
doutUnit]
reached the value set for
parameter 4-14 Motor Speed
High Limit [Hz].
Function:
fieldbus application.
Function:
4
4
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents