6-** Analog In/Out - Danfoss VLT Midi Drive FC 280 Programming Manual

Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Parameter Lists
Parameter # Parameter description
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-34
On Delay, Digital Output
5-35
Off Delay, Digital Output
5-4* Relay
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5
5
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-6* Pulse Output
Terminal 27 Pulse Output
5-60
Variable
5-62
Pulse Output Max Freq 27
5-7* 24V Encoder Input
Term 32/33 Pulses Per
5-70
Revolution
5-71
Term 32/33 Encoder Direction
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
5-93
Pulse Out 27 Bus Control
5-94
Pulse Out 27 Timeout Preset

5.2.7 6-** Analog In/Out

Parameter #
6-0* Analog I/O Mode
6-00
6-01
6-1* Analog Input 53
6-10
6-11
6-14
6-15
6-16
6-18
6-19
6-2* Analog Input 54
6-20
6-21
6-22
6-23
110
Parameter description
Live Zero Timeout Time
Live Zero Timeout Function
Terminal 53 Low Voltage
Terminal 53 High Voltage
Terminal 53 Low Ref./Feedb. Value
Terminal 53 High Ref./Feedb.
Value
Terminal 53 Filter Time Constant
Terminal 53 Digital Input
Terminal 53 mode
Terminal 54 Low Voltage
Terminal 54 High Voltage
Terminal 54 Low Current
Terminal 54 High Current
Danfoss A/S © 07/2016 All rights reserved.
®
VLT
Midi Drive FC 280
Default value
[0] No operation
0.01 s
0.01 s
Size Related
0.01 s
0.01 s
4 Hz
32000 Hz
0 N/A
Size Related
4 Hz
32000 Hz
0 N/A
Size Related
[0] No operation
5000 Hz
1024 N/A
[0] Clockwise
0 N/A
0 %
0 %
Default value
4 set-up
10 s
All set-ups
[0] Off
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 N/A
All set-ups
Size Related
All set-ups
0.01 s
All set-ups
[0] No operation
All set-ups
[1] Voltage mode
1 set-up
0.07 V
All set-ups
10 V
All set-ups
4 mA
All set-ups
20 mA
All set-ups
4 set-up
Change
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
Change during
Conversion
operation
index
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-2
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-5
TRUE
-5
Conversio
Type
n index
-
Uint8
-2
uint16
-2
uint16
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-
Uint8
0
Uint32
0
Uint16
-
Uint8
0
Uint32
-2
Uint16
-2
Uint16
Type
Uint8
Uint8
Uint16
Uint16
Int32
Int32
Uint16
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
MG07C302

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents