Glcp Layout; Display Area; Display Menu Keys; Navigation Keys And Indicator Lights (Leds) - Danfoss VLT Midi Drive FC 280 Programming Manual

Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Programming

3.1.5 GLCP Layout

The GLCP is divided into 4 functional groups (see
Illustration 3.8).
3
3
A. Display area
B. Display menu keys
C. Navigation keys and indicator lights (LEDs)
D. Operation keys and reset
1
2
A
4
6
B
7
10
C
On
15
Warn.
16
Alarm
17
D
18
Illustration 3.8 Graphic Local Control Panel (GLCP)
A. Display area
The display area is activated when the frequency converter
receives power from the mains voltage, a DC bus terminal,
or a 24 V DC external supply.
The information shown on the LCP can be customized for
user applications. Select options in the Quick Menu Q3-13
Display Settings.
Display
1
2
3
4
5
Table 3.8 Legend to Illustration 3.8, Display Area
18
Status
1(1)
7.83 A
36.4 kW
799 RPM
0.000
53.2 %
Auto Remote Ramping
Quick
Main
Alarm
Status
Menu
Menu
Log
OK
Hand
Auto
Reset
Off
on
on
19
20
Parameter number
Default setting
0-20
[1602] Reference [%]
0-21
[1614] Motor Current
0-22
[1610] Power [kW]
0-23
[1613] Frequency
0-24
[1502] kWh Counter
Danfoss A/S © 07/2016 All rights reserved.
®
VLT
Midi Drive FC 280
B. Display menu keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
6
7
8
Main Menu
3
9
Alarm Log
Table 3.9 Legend to Illustration 3.8, Display Menu Keys
5
C. Navigation keys and indicator lights (LEDs)
Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local operation. There are also 3
9
frequency converter status indicator lights in this area.
8
10
11
11
12
12
Navigation
13
13
14
14
Table 3.10 Legend to Illustration 3.8, Navigation Keys
21
Indicator
15
16
17
Table 3.11 Legend to Illustration 3.8, Indicator Lights (LEDs)
Key
Function
Status
Shows operational information.
Allows access to programming parameters
Quick
for initial set-up instructions and many
Menu
detailed application instructions.
Allows access to all programming
parameters.
Shows a list of current warnings, the last 10
alarms, and the maintenance log.
Key
Function
Reverts to the previous step or list in the
Back
menu structure.
Cancels the last change or command as long
Cancel
as the display mode has not changed.
Press for a definition of the function being
Info
shown.
To move between items in the menu, use the
keys
4 navigation keys.
Press to access parameter groups or to
OK
enable a selection.
Light
ON turns on when the frequency
converter receives power from the
On
Green
mains voltage, a DC bus terminal,
or a 24 V external supply.
When warning conditions are met,
the yellow WARN LED turns on,
Warn
Yellow
and text appears in the display
area identifying the problem.
A fault condition causes the red
Alarm
Red
alarm LED to flash, and an alarm
text is shown.
Function
MG07C302