Parameter Descriptions
1-14 Damping Gain
Range:
120
[ 0 -
%
250 %]
*
4
4
1-15 Low Speed Filter Time Const.
Range:
Size related
*
s]
1-16 High Speed Filter Time Const.
Range:
Size related
*
s]
1-17 Voltage filter time const.
Range:
Size
related
s]
*
1-20 Motor Power
Option:
[2]
0.12 kW - 0.16 hp
[3]
0.18 kW - 0.25 hp
[4]
0.25 kW - 0.33 hp
[5]
0.37 kW - 0.5 hp
[6]
0.55 kW - 0.75 hp
[7]
0.75 kW - 1 hp
[8]
1.1 kW - 1.5 hp
[9]
1.5 kW - 2 hp
[10]
2.2 kW - 3 hp
[11]
3 kW - 4 hp
[12]
3.7 kW - 5 hp
[13]
4 kW - 5.4 hp
[14]
5.5 kW - 7.5 hp
[15]
7.5 kW - 10 hp
32
Function:
The damping gain stabilizes the PM machine.
The value of damping gain controls the dynamic
performance of the PM machine. High damping
gain gives high dynamic performance, and low
damping gain gives low dynamic performance.
The dynamic performance is related to the
machine data and load type. If the damping gain
is too high or low, the control becomes unstable.
Function:
[ 0.01 - 20
This time constant is used below
10% rated speed. Obtain quick
control through a short damping
time constant. However, if this value
is too short, the control becomes
unstable.
Function:
[ 0.01 - 20
This time constant is used above
10% rated speed. Obtain quick
control through a short damping
time constant. However, if this value
is too short, the control becomes
unstable.
Function:
[ 0.001 - 1
Reduce the influence of high
frequency ripple and system
resonance in the calculation of supply
voltage. Without this filter, the ripples
in the currents can distort the
calculated voltage and affect the
stability of the system.
Function:
Danfoss A/S © 07/2016 All rights reserved.
®
VLT
Midi Drive FC 280
1-20 Motor Power
Option:
[16]
[17]
[18]
[19]
[20]
1-22 Motor Voltage
Range:
Size
related
*
1-23 Motor Frequency
Range:
Size
related
*
1-24 Motor Current
Range:
Size
related
*
1-25 Motor Nominal Speed
Range:
Size related
1-26 Motor Cont. Rated Torque
Range:
Size
related
*
11 kW - 15 hp
15 kW - 20 hp
18.5 kW - 25 hp
22 kW - 30 hp
30 kW - 40 hp
Function:
[50 - 1000
Enter the nominal motor voltage
V]
according to the motor nameplate
data. The default value corresponds to
the nominal rated output of the unit.
Function:
NOTICE
This parameter cannot be adjusted
while the motor is running.
[ 20 -
Select the motor frequency value from the
500
motor nameplate. For 87 Hz operation with
Hz]
230/440 V motors, set the value according to
the nameplate data for 230 V/50 Hz. Adapt
parameter 4-14 Motor Speed High Limit [Hz] and
parameter 3-03 Maximum Reference to the 87
Hz application.
Function:
[ 0.01 -
Enter the nominal motor current
10000.00 A]
value from the motor nameplate
data. This data is used for
calculating motor torque, motor
thermal protection, and so on.
Function:
[50 - 60000
Enter the nominal motor speed
*
RPM]
value from the motor nameplate
data. This data is used for
calculating automatic motor
compensations.
Function:
[ 0.1 -
Enter the value from the motor nameplate
10000
data. The default value corresponds to the
Nm]
nominal rated output. This parameter is
available when parameter 1-10 Motor