Parameter Descriptions
37-13 Pos. PID Output Clamp
Range:
Function:
1000
[1 -
This parameter clamps the total output of
*
10000 ]
the PID. A setting of 1000 corresponds to
100% of parameter 32-80 Maximum Allowed
Velocity.
37-14 Pos. Ctrl. Source
Select the control source for positioning control.
Option:
[0]
DI
*
[1]
FieldBus
37-15 Pos. Direction Block
Use this parameter to configure whether to block a direction,
and the direction to be blocked.
Option:
[0]
No Blocking
*
[1]
Block Reverse
[2]
Block Forward
37-17 Pos. Ctrl Fault Behaviour
This parameter determines the behavior of the frequency
converter after a fault is detected.
Option:
[0]
Ramp Down&Brake
*
[1]
Brake Directly
37-18 Pos. Ctrl Fault Reason
READ-ONLY PARAMETER: The current fault reason of the alarm.
POSITION CTRL FAULT is shown in this parameter.
Option:
[0]
No Fault
*
[1]
Homing Needed
[2]
Pos. HW Limit
[3]
Neg. HW Limit
[4]
Pos. SW Limit
[5]
Neg. SW Limit
[7]
Brake Wear Limit
[8]
Quick Stop
[9]
PID Error Too Big
[12]
Rev. Operation
[13]
Fwd. Operation
[20]
Can not find home position
37-19 Pos. New Index
Range:
Function:
0
[0 - 255 ]
The currently latched index number.
*
MG07C302
Programming Guide
Function:
Function:
Function:
Function:
Danfoss A/S © 07/2016 All rights reserved.
4
4
101