18-** Data Readouts 2; 21-** Ext. Closed Loop; 22-** Application Functions - Danfoss VLT Midi Drive FC 280 Programming Manual

Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Parameter Lists

5.2.17 18-** Data Readouts 2

Parameter #
Parameter description
18-9* PID Readouts
18-90
Process PID Error
18-91
Process PID Output
18-92
Process PID Clamped Output
18-93
Process PID Gain Scaled Output

5.2.18 21-** Ext. Closed Loop

Parameter #
Parameter description
21-0* Ext. CL Autotuning
21-09
Extended PID Enable
21-1* Ext. CL 1 Ref./Fb.
21-11
Ext. 1 Minimum Reference
21-12
Ext. 1 Maximum Reference
21-13
Ext. 1 Reference Source
21-14
Ext. 1 Feedback Source
21-15
Ext. 1 Setpoint
21-17
Ext. 1 Reference [Unit]
21-18
Ext. 1 Feedback [Unit]
21-19
Ext. 1 Output [%]
Ext. CL 1 PID
21-20
Ext. 1 Normal/Inverse Control
21-21
Ext. 1 Proportional Gain
21-22
Ext. 1 Integral Time
21-23
Ext. 1 Differentation Time
21-24
Ext. 1 Dif. Gain Limit

5.2.19 22-** Application Functions

Parameter #
Parameter description
22-4* Sleep Mode
22-40
Minimum Run Time
22-41
Minimum Sleep Time
22-43
Wake-Up Speed [Hz]
22-44
Wake-Up Ref./FB Diff
22-45
Setpoint Boost
22-46
Maximum Boost Time
22-47
Sleep Speed [Hz]
22-6* Broken Belt Detection
22-60
Broken Belt Function
22-61
Broken Belt Torque
22-62
Broken Belt Delay
MG07C302
Programming Guide
Default value
4 set-up
0 %
All set-ups
0 %
All set-ups
0 %
All set-ups
0 %
All set-ups
Default value
4 set-up
[0] Disabled
All set-ups
0 ExtPID1Unit
All set-ups
100 ExtPID1Unit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
0 ExtPID1Unit
All set-ups
0 ExtPID1Unit
All set-ups
0 ExtPID1Unit
All set-ups
0 %
All set-ups
[0] Normal
All set-ups
0.01 N/A
All set-ups
10000 s
All set-ups
0 s
All set-ups
5 N/A
All set-ups
Default value
4 set-up
10 s
All set-ups
10 s
All set-ups
10 N/A
All set-ups
10 %
All set-ups
0 %
All set-ups
60 s
All set-ups
0 N/A
All set-ups
[0] Off
All set-ups
10 %
All set-ups
10 s
All set-ups
Danfoss A/S © 07/2016 All rights reserved.
Change during
Conversion
operation
index
FALSE
-1
FALSE
-1
FALSE
-1
FALSE
-1
Change during
Conversion
operation
index
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-1
Change during
Conversion
operation
index
TRUE
0
TRUE
0
TRUE
-1
TRUE
0
TRUE
0
TRUE
0
TRUE
-1
TRUE
-
TRUE
0
TRUE
0
Type
Int16
Int16
Int16
Int16
5
5
Type
Uint8
Int32
Int32
Uint8
Uint8
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint32
Uint16
Uint16
Type
Uint16
Uint16
Uint16
Uint8
Int8
Uint16
Uint16
Uint8
Uint8
Uint16
119