Parameter Descriptions
16-60 Digital Input
Range:
Function:
0
[0 -
View the actual state of the digital inputs 18, 19,
*
65535 ]
27, 29, 32, and 33.
Bit 0
Digital input terminal 33
Bit 1
Digital input terminal 32
Bit 2
Digital input terminal 29
Bit 3
Digital input terminal 27
Bit 4
Digital input terminal 19
Bit 5
Digital input terminal 18
Bit 6–15 Unused
Table 4.6 Bits Definition
16-61 Terminal 53 Setting
Show the setting of input terminal 53.
Option:
[1]
Voltage mode
[6]
Digital input
16-62 Analog Input 53
Range:
Function:
1
[0 - 20 ]
View the actual value at input 53.
*
16-63 Terminal 54 Setting
Option:
Function:
View the setting of input terminal 54.
[0]
Current mode
[1]
Voltage mode
16-64 Analog Input AI54
Range:
Function:
1
[0 - 20 ]
View the actual value at input 54.
*
16-65 Analog Output 42 [mA]
Range:
Function:
0 mA
[0 - 20
View the actual value at output 42. The
*
mA]
value shown reflects the selections in
parameter 6-90 Terminal 42 Mode and
parameter 6-91 Terminal 42 Analog Output.
16-66 Digital Output
Range:
Function:
0
[0 - 15 ]
View the binary value of all digital outputs.
*
16-67 Pulse Input #29 [Hz]
Range:
Function:
0
[0 - 130000 ] View the actual frequency rate on terminal 29.
*
MG07C302
Programming Guide
16-68 Pulse Input 33 [Hz]
Range:
0
*
16-69 Pulse Output 27 [Hz]
Range:
0
*
16-71 Relay Output
Range:
0
*
16-72 Counter A
Range:
0
*
Function:
16-73 Counter B
Range:
0
*
16-74 Prec. Stop Counter
Range:
0
*
16-80 Fieldbus CTW 1
Range:
0
*
16-82 Fieldbus REF 1
Range:
0
*
Danfoss A/S © 07/2016 All rights reserved.
Function:
[0 - 130000 ] View the actual value of the frequency
applied at terminal 33 as an impulse input.
Function:
[0 - 40000 ] View the actual value of impulses applied to
terminal 27 in digital output mode.
Function:
[0 - 65535 ]
View the settings of all relays.
Function:
[-32768 -
View the present value of counter A. Counters are
32767 ]
useful as comparator operands, see
parameter 13-10 Comparator Operand.
The value can be reset or changed either via
digital inputs (parameter group 5-1* Digital Inputs),
or by using an SLC action (parameter 13-52 SL
Controller Action).
Function:
[-32768 -
View the present value of counter B. Counters are
32767 ]
useful as comparator operands
(parameter 13-10 Comparator Operand).
The value can be reset or changed either via
digital inputs (parameter group 5-1* Digital Inputs)
or by using an SLC action (parameter 13-52 SL
Controller Action).
Function:
[0 - 2147483647 ] Show the current value of the precise
stop counter.
Function:
[0 -
View the 2-byte control word (CTW) received
65535 ]
from the bus master. Interpretation of the CTW
depends on the fieldbus option installed and the
CTW profile selected in parameter 8-10 Control
Word Profile. For more information, see relevant
fieldbus manuals.
Function:
[-32768 -
To set the reference value, view the 2-byte
32767 ]
word sent with the control word from the
bus master. For more information, refer to
the relevant fieldbus manual.
4
4
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents