10-** Can Fieldbus; 12-** Ethernet - Danfoss VLT Midi Drive FC 280 Programming Manual

Hide thumbs Also See for VLT Midi Drive FC 280:
Table of Contents

Advertisement

Parameter Lists
Parameter #
9-90
9-91
9-92
9-93
9-94
9-99

5.2.11 10-** CAN Fieldbus

5
5
Parameter #
10-0* Common Settings
10-01
10-02
10-05
10-06
10-3* Parameter Access
10-31
10-33

5.2.12 12-** Ethernet

Parameter #
12-0* IP Settings
12-00
12-01
12-02
12-03
12-04
12-05
12-06
12-07
12-08
12-09
12-1* Ethernet Link Parameters
12-10
12-11
12-12
12-13
12-14
12-8* Other Ethernet Services
12-80
12-81
12-82
12-89
12-9* Advanced Ethernet Services
12-90
12-91
12-92
12-93
114
Parameter description
Changed Parameters (1)
Changed Parameters (2)
Changed Parameters (3)
Changed Parameters (4)
Changed Parameters (5)
Profibus Revision Counter
Parameter description
Baud Rate Select
Node ID
Readout Transmit Error Counter
Readout Receive Error Counter
Store Data Values
Store Always
Parameter description
IP Address Assignment
IP Address
Subnet Mask
Default Gateway
DHCP Server
Lease Expires
Name Servers
Domain Name
Host Name
Physical Address
Link Status
Link Duration
Auto Negotiation
Link Speed
Link Duplex
FTP Server
HTTP Server
SMTP Service
Transparent Socket Channel Port
Cable Diagnostic
Auto Cross Over
IGMP Snooping
Cable Error Length
Danfoss A/S © 07/2016 All rights reserved.
®
VLT
Midi Drive FC 280
Default value
4 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4 set-up
[20] 125 Kbps
1 set-up
127 N/A
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
[0] Off
All set-ups
[0] Off
1 set-up
Default value
4 set-up
[10] DCP
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[0] No Link
All set-ups
Size Related
All set-ups
[1] On
1 set-up
[0] None
1 set-up
[1] Full Duplex
1 set-up
[0] Disabled
1 set-up
[0] Disabled
1 set-up
[0] Disabled
1 set-up
4000 N/A
1 set-up
[0] Disabled
1 set-up
[1] Enabled
1 set-up
[1] Enabled
1 set-up
0 N/A
1 set-up
Change during
Conversion
operation
index
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TRUE
0
Change during
Conversion
operation
index
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
Change during
Conversion
operation
index
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
Type
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Type
Uint8
Uint8
Uint8
Uint8
uint8
Uint8
Type
Uint8
OctStr[4]
OctStr[4]
OctStr[4]
OctStr[4]
TimD
OctStr[4]
VisStr[48]
VisStr[48]
VisStr[17]
Uint8
TimD
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint16
MG07C302