Parameter Lists

5.2 Parameter Lists

5.2.1 0-** Operation and Display

Parameter #
Parameter description
0-0* Basic Settings
0-01
Language
0-03
Regional Settings
0-04
Operating State at Power-up
0-06
GridType
0-07
Auto DC Braking
0-1* Set-up Operations
0-10
Active Set-up
0-11
Programming Set-up
0-12
Link Setups
0-14
Readout: Edit Set-ups / Channel
0-16
Application Selection
0-2* LCP Display
0-20
Display Line 1.1 Small
0-21
Display Line 1.2 Small
0-22
Display Line 1.3 Small
0-23
Display Line 2 Large
0-24
Display Line 3 Large
0-3* LCP Custom Readout
0-30
Custom Readout Unit
0-31
Custom Readout Min Value
0-32
Custom Readout Max Value
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-42
[Auto on] Key on LCP
0-44
[Off/Reset] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password

5.2.2 1-** Load and Motor

Parameter #
Parameter description
1-0* General Settings
1-00
Configuration Mode
1-01
Motor Control Principle
1-03
Torque Characteristics
1-06
Clockwise Direction
1-08
Motor Control Bandwidth
1-1* Motor Selection
MG07C302
Programming Guide
Default value
4 set-up
[0] English
1 set-up
[0] International
1 set-up
[0] Resume
All set-ups
Size Related
1 set-up
[1] On
1 set-up
[1] Set-up 1
1 set-up
[9] Active Set-up
1 set-up
[20] Linked
All set-ups
0 N/A
All set-ups
[0] None
1 set-up
1602
All set-ups
1614
All set-ups
1610
All set-ups
1613
All set-ups
1502
All set-ups
[1] %
1 set-up
0 CustomRea-
doutUnit
1 set-up
100 CustomRea-
doutUnit
1 set-up
[]
1 set-up
[]
1 set-up
[]
1 set-up
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[0] No copy
1 set-up
[0] No copy
1 set-up
0 N/A
1 set-up
Default value
4 set-up
[0] Open Loop
All set-ups
[1] VVC+
All set-ups
[0] Constant torque
All set-ups
[0] Normal
1 set-up
Size Related
1 set-up
Danfoss A/S © 07/2016 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
FALSE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
0
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
0
Change during
Conversion
operation
index
TRUE
-
FALSE
-
FALSE
-
FALSE
-
FALSE
-
Type
Uint8
Uint8
Uint8
Uint8
5
5
Uint8
Uint8
Uint8
Uint8
Int32
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Int32
Int32
VisStr[21]
VisStr[26]
VisStr[26]
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
105