Parameter Lists

5.2.5 4-** Limits/Warnings

Parameter #
Parameter description
4-1* Motor Limits
4-10
Motor Speed Direction
4-12
Motor Speed Low Limit [Hz]
4-14
Motor Speed High Limit [Hz]
4-16
Torque Limit Motor Mode
4-17
Torque Limit Generator Mode
4-18
Current Limit
4-19
Max Output Frequency
4-2* Limit Factors
4-20
Torque Limit Factor Source
4-21
Speed Limit Factor Source
4-22
Break Away Boost
4-3* Motor Fb Monitor
4-30
Motor Feedback Loss Function
4-31
Motor Feedback Speed Error
4-32
Motor Feedback Loss Timeout
4-4* Adj. Warnings 2
4-40
Warning Freq. Low
4-41
Warning Freq. High
4-42
Adjustable Temperature Warning
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-6* Speed Bypass
4-61
Bypass Speed From [Hz]
4-63
Bypass Speed To [Hz]

5.2.6 5-** Digital In/Out

Parameter # Parameter description
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-19
Terminal 37/38 Safe Torque Off
MG07C302
Programming Guide
Default value
4 set-up
[0] Clockwise
All set-ups
0 Hz
All set-ups
65 Hz
All set-ups
Size Related
All set-ups
100 %
All set-ups
Size Related
All set-ups
Size Related
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
[0] Off
All set-ups
[2] Trip
All set-ups
20 Hz
All set-ups
0.05 s
All set-ups
Size Related
All set-ups
Size Related
All set-ups
0 N/A
All set-ups
0 A
All set-ups
Size Related
All set-ups
-4999 N/A
All set-ups
4999 N/A
All set-ups
-4999
ProcessCtrlUnit
All set-ups
4999
ProcessCtrlUnit
All set-ups
[1] On
All set-ups
0 Hz
All set-ups
0 Hz
All set-ups
Default value
[0] PNP
[0] Input
[8] Start
[10] Reversing
Size Related
[14] Jog
[0] No operation
[16] Preset ref bit 0
[1] Safe Torque Off Alarm
Danfoss A/S © 07/2016 All rights reserved.
Change during
Conversion
operation
index
FALSE
-
FALSE
-1
FALSE
-1
TRUE
0
TRUE
0
TRUE
0
FALSE
-1
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
0
TRUE
-2
TRUE
-1
TRUE
-1
TRUE
0
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-3
FALSE
-
TRUE
-1
TRUE
-1
4 set-up
Change
during
operation
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
5
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
uint16
uint16
Uint8
Uint32
Uint32
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint16
Conversio
Type
n index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
109
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents