Korg KROSS Parameter Manual page 103

Hide thumbs Also See for KROSS:
Table of Contents

Advertisement

Copy from Program
This function is available on every page in Combination mode. It
copies Effects settings from a selected Program to the current
Combination. This lets the Program sound the same as it did in
Program mode.
1. Use Program to select the copy-source program.
2.Select the IFXs used, MFXs options to specify which, if
any, of the Program's effects settings to copy.
IFXs: The settings of all insert effect settings (the contents of
the Insert FX setup page and the IFX1–5 effect parameters) of
the copy-source program will be copied.
MFXs: All master effect settings of the copy-source program
will be copied.
Bus Select settings made automatically when you execute Copy From
Program
When you execute Copy From Program, each timbre's Bus
Select setting is automatically set as follows according to
various conditions.
• If IFX is checked, all IFX as well as the Bus Select setting
of the copy-source will be copied to the copy-destination
timbre. In addition, all timbres other than the copy-
destinationwhere Bus Select is set to IFX1–5 will be
automatically changed to L/R.
Note: Note: Timbres other than the copy-destination that are
set to Off or DKit will not be changed.
• If IFXs is unchecked, IFX and Bus Select settings will not
be copied; the Bus Select of the copy-destination program
will be automatically changed to L/R, regardless of whether
it had been set to Off, IFX1–5, or DKit.
Note: Automatic settings will not be made for timbres other
than the copy-destination.
• In addition to the above, if the copy-source program is a
drum program and the P-FX ROUTING> BUS page DKIT-
SET setting is checked, the copy-destination timbre's Bus
Select will be set to DKit regardless of whether IFXs is
checked. Also, the DKit IFX Patch setting will be reset to
the default state.
3. If StepSeq is checked, the step sequencer settings of the
copy-source program will also be copied. The step
sequencer's drum program will be assigned to timbre 16.
4. If you check "Arp," the Program's arpeggiator settings will
also be copied.
If this is On (checked), the arpeggiator settings of the copy-
source program will be copied to the "Arp" you specify in step
7, and that arpeggiator's Arpeggiator Run setting will be
turned on and assigned to the copy-destination timbre
("Arpeggiator Assign").
5. If you check "with Drum Track," the Drum Track Pattern
settings of the copy-source program will also be copied.
If this is On (checked), the Drum Track Pattern settings of the
copy-source program will be copied to the "Drum Track" you
specify in step 8.
The MIDI channel specified for the Drum Track copy-
destination timbre will be used.
6. Use the To field to specify the copy-destination timbre.
The parameters for each timbre will be initialized. The copy-
source program will be assigned to Program (COMBI> PROG
Program Select on page 71).
Combination: FUNCTION Copy from Program
• The MIDI Channel (C–TIMBRE> MIDI) setting will not
change if "Arp" is checked. If "Arp" is unchecked, MIDI
Channel will be automatically set to G ch.
• The Status (COMBI> PROG) setting will automatically be
set to INT.
7. Use the "Arp" field to select the copy-destination arpeggia-
tor; either A or B.
8. Use the "Drum Track" to specify the destination timbre
where the drum track program will be copied.
Hold Balance
1. Choose this function to turn it on (select the check mark).
2. When you adjust any timbre's volume setting, the other
timbre volume settings will change to maintain the balance.
This is convenient when you want to adjust the overall vol-
ume.
Detune BPM Adjust
Detune BPM Adjust is available on the C–TIMBRE> PITCH
opage.
This function changes a loop's tempo by changing the Timbre's
Detune parameter. The multisample data itself is not altered. Since
this alters the pitch of the loop along with the tempo, it's generally
intended for un-pitched percussive loops.
Note: Using Detune BPM Adjust will over-write any previous
Detune settings.
1. Go to the Pitch tab of the Timbre Parameters page.
2. Select the Detune parameter for the desired Timbre.
Detune BPM Adjust is available only when the Detune
parameter has been selected. Otherwise, the menu selection will be
grayed out.
1. In From, specify the loop's original BPM value. In To, spec-
ify the desired BPM value.
The appropriate Detune value will be calculated automatically
from these two values.
2. For example, if you set From to 60 bpm and To to 120 bpm,
Detune will be set to +1200 (one octave up).
Note: Since this function does not affect the multisample data
itself, and always over-writes the previous Detune amount, using
it repeatedly has no cumulative effect.
Copy Arpeggiator
Copy Arpeggiator is available on the COMBI> ARP and C–ARP
pages.
This function can copy arpeggiator settings from another location
to the current Combi.
1. In From, select the source of the arpeggiator you wish to
copy.
95

Advertisement

Table of Contents
loading

Table of Contents