Rmon Hcalarm - Cisco nexus 3000 series Command Reference Manual

Nx-os system management
Hide thumbs Also See for nexus 3000 series:
Table of Contents

Advertisement

Chapter
System Management Commands
S e n d c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m

rmon hcalarm

To configure a high-capacity Remote Monitoring (RMON) alarm, use the rmon hcalarm command. To
remove a high-capacity RMON alarm, use the no form of this command.
Syntax Description
alarm-no
MIB-obj
sample-interval
absolute
delta
startupalarm
startup-alarm-type
rising-threshold
rising-threshold-value
event-index
falling-threshold
fall-threshold-value
owner name
Command Default
None
Command Modes
Global configuration mode
Command History
Release
5.0(3)U1(1)
OL-29557-04
rmon hcalarm alarm-no MIB-obj sample-interval {absolute | delta} startupalarm
startup-alarm-type rising-threshold rising-threshold-value event-index falling-threshold
fall-threshold-value [event-index] [owner name]
no rmon hcalarm alarm-no MIB-obj sample-interval {absolute | delta} startupalarm
startup-alarm-type rising-threshold rising-threshold-value event-index falling-threshold
fall-threshold-value [event-index] [owner name]
Alarm number. The range is from 1 to 65535.
MIB object to monitor.
The MIB object must be an existing SNMP MIB object in standard dot
notation; for example, 1.3.6.1.2.1.2.2.1.17.83886080.
Sample interval at which the switch collects a sample value of the MIB
object. The range is from 1 to 700000 seconds.
Specifies the sample type as absolute.
Specifies the sample type as delta.
Configures the startup alarm type.
Startup alarm type. The range is from 1 to 3, where 1 is rising, 2 is falling,
and 3 is rising or falling.
Configures the rising threshold value at which the switch triggers a rising
alarm or resets a falling alarm.
Rising threshold value. The range is from 0 to 18446744073709551615.
Event or action that the switch takes when an alarm, rising or falling,
triggers. The event index range is from 0 to 65535.
Configures the falling threshold value at which the switch triggers a falling
alarm or resets a rising alarm.
Falling threshold value. The range is from 0 to 18446744073709551615.
Note
(Optional) Specifies an owner for the alarm. The name can be any
alphanumeric string.
Modification
This command was introduced.
The falling threshold value must be less than the rising threshold.