Set Lgmp Server Robust-Variable - Avaya 106760804 Command Reference Manual

Avaya multi service switch user guide
Table of Contents

Advertisement

Chapter 10

set lgmp server robust-variable

Command Mode
Description
Syntax
Sample Output
Systems
10-30
Global Configuration.
Sets the LGMP server robustness variable. Omitting the parameter sets the
robustness variable to its default value of 2.
set lgmp server robust-variable [<rv-val>]
Table 10-16. Parameters, Keywords, Arguments
Name
Definition
<rv-val>
The robustness variable that defines the scalar used to calculate the
timeout for an LGMP server non-distributor to become a distributor.
The scalar is used to calculate non-distributor timeout. The range is
2 to 10.
The following example sets the robustness variable to 4.
(configure)# set lgmp server robust-variable 4
LGMP Server Robustness Variable successfully set to
4
P550R, P580, P880, and P882.
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

P580P882

Table of Contents