Chapter 18
set port internal-error-shutdown
Command Mode
Description
Syntax
Sample Output
Systems
18-4
Global Configuration.
Enables or disables internal error detection and recovery (IEDR) on a port
or ports
To Enable:
set port internal-error-shutdown {<mod-num> | <mod-
swport-spec> | all-ports} enable
To Disable:
set port internal-error-shutdown {{<mod-num> | <mod-
swport-spec>}| all-ports} disable
Table 18-2. Parameters, Keywords, Argument
Name
{<mod-num> | <mod-
swport-spec>}
all-ports
The following example enables IEDR on all ports on the module in slot 3.
(configure)# set port internal-error-shutdown 3 enable
P550R, P580, P880, and P882.
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Definition
The slot number of the module, and, either port
number, or range of port numbers. Enter the port
ranges in the format Px-Py. For example:
• To specify port 1 on the module in slot 3, enter
3/1.
• To specify ports 1 through 5 on the module in
slot 3, enter 3/1-5.
Enables or disables IEDR on all ports on all modules in
the switch.