Example
AT&F?
&F: 0
OK

Z, Reset to Default Configuration

This command drops the current call, and resets the values to default configuration.
Command Type
Set
Read
Test
The following table shows the Z parameters.
<Parameter>
<value>
Example
ATZ0
OK

Sleep Mode Commands

When the G24-L is connected using RS232 connection to external device, a sleep mechanism is
available. In order to improve the power consumption, the G24-L supports a low-power
consumption mode, called "Sleep mode". The G24-L has internal decision conditions for entering
and exiting sleep mode. As the terminal and the G24-L operate in a combined system, and as the
communication between the G24-L and the terminal must be reliable, there should be a
mechanism agreed upon by both the G24-L and the terminal to co-ordinate their separate sleep
mode entering and exiting sequences. The G24-L will not enter sleep mode unless the terminal
April 15, 2008
Syntax
Response/Action
ATZ<value>
OK
or:
+CMS ERROR: <err>
Table 3-134: Z Parameters
0
Set to user profile 0
1
Set to user profile 1
The default value is 0.
G24-L AT Commands Reference Manual
Chapter 3: AT Commands Reference
Remarks
The Read command for Z is not
defined, and therefore is not supported
by the G24-L. The G24-L returns an
error.
The Test command for Z is not
defined, and therefore is not
supported by the G24-L. The
G24-L returns an error
Description
.