Audio
The following table shows the S94 parameters.
Example
ATS94=0
OK
ATS94=2
+CME ERROR: <err>
ATS94?
000
OK
S96, Echo Canceling
This command suppresses a large amount of the output sound picked up by the input device
(cancels all echo). S96 value is saved in the Flex.
The following table explains the use of the ATS96 set.
ATS96
0
0
1
1
Command Type
Set
Read
Test
3-162
Table 3-105: S94 Parameters
<Parameter>
<n>
0
Disable sidetone
1
Enable sidetone
On power up the sidetone is enabled.
//Disable sidetone
//Sidetone disabled
Table 3-106: ATS96 and ATS94 Behavior
ATS94
Echo Cancel
0
Disabled
1
Disabled
0
Enabled
1
Enabled
Syntax
Response/Action
ATS96=<n>
OK
or:
+CME ERROR: <err>
ATS96?
<000-disabled,
001-enabled>
OK
or:
+CME ERROR: <err>
ATS96=?
+CME ERROR: <err>
G24-L AT Commands Reference Manual
Description
Noise Suppress
Disabled
Disabled
Enabled
Enabled
Remarks
The Set command sets the echo
canceling and noise suppression status.
The Read command returns the echo
canceling and noise suppression status.
ST
Disabled
Enabled
Disabled
Disabled
April 15, 2008