Access
Command
Type
Set
Read
The following table shows the +EMPC parameters.
<Parameter>
<pin>
<action>
<unlock>
<reset>
3-188
Syntax
+EMPC=<pin>,<action>
+EMPC:<unlock>,<reset>
OK
or:
+CME ERROR: <err>
+EMPC?
+EMPC:3,<reset>
OK
or:
+CME ERROR <err>
Table 3-125: +EMPC Parameters
Subsidy Lock pin code.
0
Unlock subsidy
1
Reset subsidy
0
Correct pin code is entered
1
Wrong pin code is entered
2
Wait
3
No meaning
0
No subsidy lock
1
Subsidy lock / Reset not allowed
2
Subsidy unlock / Reset allowed
G24-L AT Commands Reference Manual
Response/Action
The Set command checks the
password with requested action
type. All parameters are
mandatory field. If the pin is
wrong or inserts wrong action, no
action is taken towards the G24-L,
and an error message, +CME
ERROR, is returned to the
terminal. The Set command issued
gives the code corresponding to
the required action.
The read command returns the
current EMPC reset value only.
Description
Remarks
April 15, 2008