Test G24-L Communication

This is a preliminary step. During this step, the ability to communicate with the G24-L using AT
commands is tested.
Figure 4-5: Test G24-L Communication
Communication example:
AT
ATE1
AT
OK

Basic Configuration

These are optional steps. If required, specific RS232 pin behavior can be selected. Extended error
notification is recommended for debugging and field-support purposes.
Figure 4-6: Basic Configuration
April 15, 2008
Start
Error
No Echo
Send 'AT'
OK
End
//By default, the echo should be enabled
//Confirm that G24-L replies with OK
Configure the RS232 Connection (Optional)
Baud rate, line behavior and flow control
(for example, "AT+CBUAD=115200", "AT&Cx", "AT&Dx", "AT&Kx")
Note: If the baud rate has been changed, you must change the baud rat e of the UART as
Enable Extended Error Messages (Optional)
(for example, "AT+CMEE=2 or 1")
Basic Commands (Optional)
G24-L AT Commands Reference Manual
Chapter 4: Using the Commands
Check RS232 Connection or
Change UART Baud Rate