7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
120
Default value
MD 172
Input of switchover speed for the current controller adaptation. The phase current controller
gain is adapted as a function of speed. The specified speed is the speed at which the phase
current controllers reach their maximum gain.
Phase current
controller gain
4 x gain set
in MD 116
MD 116
150
Default value
Display machine data for module identifier.
Value table:
Bit 0-3
Bit 4-7
Bit 8-11
Bit 8-11
Bit 12-15
7–18
More user manuals on
Switchover speed current controller adaptation motor 1
Lower input limit
500
MD 337
Module identifier
Lower output limit
Motor
0H
measuring
circuit
1H
FH Not fitted
Not assigned
Not assigned
Spindle
0H
measuring
circuit
1H
FH Not fitted
Not fitted
ManualsBase.com
Upper input limit
10 000
MD 120
Upper output limit
Measuring circuit for incremental encoder with
sinusoidal voltage signals
Measuring circuit for incremental encoder with
sinusoidal current signals
Measuring circuit
Measuring circuit for incremental encoder with
sinusoidal voltage signals
Measuring circuit for incremental encoder with
sinusoidal current signals
©
Siemens AG 1992 All Rights Reserved
12.93
Active
at once
Units
rev/min
n
Active
at once
Units
Hex